Previous Page  4 / 237 Next Page
Information
Show Menu
Previous Page 4 / 237 Next Page
Page Background

March 3, 2016

Diamond Precast Concrete Ltd.

7520 Conrad Street

Burnaby, BC V5A 2H7

Re:

Compliance with MMCD PlaƟnum SecƟon 33 44 01 - Manholes and Catchbasins

To comprehensively assess all MMCD PlaƟnum 33 44 01 requirements, the following

documents were reviewed:

1. MMCD PlaƟnum EdiƟon - SecƟon 33 44 01 Manholes and Catchbasins (with accompanying

Standard Detail Drawings S1 thru S15)

2. ASTM C478M – Standard SpecificaƟon for Circular Precast Reinforced Manhole SecƟons

3. ASTM C913 - Standard SpecificaƟon for Precast Concrete Water and Wastewater Structures

(Includes Oil-Water Separators)

4. CSA 23.4-09 – Precast Concrete Materials and ConstrucƟon

5. Diamond Precast Concrete - CerƟficate of Compliance to CSA 23.4-09

6. Diamond Precast Concrete - CerƟficate of Compliance to CSA Standard for Reinforced Circular

Manhole SecƟons and Catch Basins - CerƟfied to ASTM Standards for Canada (ASTM C478M)

7. Diamond Precast Concrete - Quality Control Manual

8. Diamond Precast Concrete - Structural Drawings

9. Standards Council of Canada - Accredited Third Party CerƟficaƟon Bodies (includes CSA)

10. Standards Council of Canada - Scope of AccreditaƟon for CSA Group (includes ICS No. 91.100.30)

MMCD PlaƟnum EdiƟon SecƟon 33 44 01 Manholes and Catchbasins

make the following

relevant references:

1.0 GENERAL .1 This secƟon must be referenced to and interpreted simultaneously with all

other secƟons perƟnent to the works described herein.

1.4 Material CerƟficaƟon .1 Products having CSA cerƟficaƟon to be used where readily available.

Product to be cerƟfied to CSA standard(s) by an approved independent third party cerƟficaƟon

body accredited by the Standards Council of Canada.

2.1 Materials

.4 Precast manhole secƟons: to be precast reinforced concrete to ASTM C478M complete

with ladder rungs.

.6 Manhole lids manufactured from precast reinforced concrete. shall be designed to

withstand H20 loading.

.8 Ladder rungs to be:

.2 To conform to .. ASTM C478M load test.

.10 Precast catchbasin secƟons:

.2 To be precast reinforced concrete to ASTM C478M.

APOC Engineering Ltd.

#410-3701 Hastings St. Burnaby B.C. V5C 2H5

604 259 0730, 778 232 9364

vwang@apocengineering.com