Canadian Standards Association

Precast concrete — Materials and construction

November 2009

B.5.2

Where the joints between slabs do not have grout keys, they may be taped for roofing or topping

applications. This taping shall be performed by the trade or general contractor who subsequently carries

out the roofing or floor topping operations.

B.5.3

Where differential camber exceeds the values specified in

Clause 12.8

, the joint might have to be

feather-grouted to a slope of 1:12. This work shall be performed by the precast concrete installer.

Licensed for/Autorisé à Jed Friesen Sold by/vendu par CSA on/le June/18/2015.